N2XKBY
Cu / XLPE / LS / PVC / DATA / PVC Deskripsi
Copper Conductor, XLPE Insulated, Lead Sheathed, Double Aluminium Tape Armor, PVC Sheathed
Aplikasi
- For indoors, outdoors, in ground and in duct. Mainly on chemical industries, refineries, petrol stations and any other locations where there is a risk that solvent, fuel and other chemicals may penetrate and low mechanical damage may occur
Konstruksi Kabel
Pelajari kode penamaan kabel →Susunan lapisan N2XKBY dari dalam ke luar — sesuai kode konstruksi Cu / XLPE / LS / PVC / DATA / PVC.
- 1
Konduktor tembaga
Copper conductorPenghantar arus utama — tembaga anil, solid / stranded / compacted.
- 2
Isolasi XLPE
Cross-linked polyethyleneIsolasi utama — suhu kerja 90 °C, kuat dielektrik tinggi, kapasitas hantar lebih besar dari PVC.
- 3
Selubung timah (lead sheath)
Lead sheathKedap air & tahan kimia — untuk lingkungan korosif, terkontaminasi hidrokarbon.
- 4
Selubung dalam PVC
Polyvinyl chlorideBantalan (bedding) — alas perisai/pelindung dan pengikat inti kabel.
- 5
Perisai pita aluminium ganda (DATA)
Double aluminium tape armourDua lapis pita aluminium — perisai non-magnetik untuk kabel inti tunggal.
- 6
Selubung luar PVC
Polyvinyl chlorideSelubung terluar — proteksi terhadap lingkungan, kelembapan, dan abrasi.
Spesifikasi Teknis
N2XKB(AL)Y 1 x (16-800) mm² 0.6/1 kV
| Nom. Cross Section Area | Overall Diameter approx. | Cable Weight approx. |
|---|---|---|
| mm² | mm | kg/km |
| 16 | 22.0 | 1,140 |
| 25 | 22.0 | 1,205 |
| 35 | 22.0 | 1,279 |
| 50 | 23.0 | 1,452 |
| 70 | 24.5 | 1,766 |
| 95 | 26.5 | 2,107 |
| 120 | 28.5 | 2,522 |
| 150 | 30.5 | 2,900 |
| 185 | 33.5 | 3,540 |
| 240 | 36.5 | 4,416 |
| 300 | 39.5 | 5,160 |
| 400 | 43.5 | 6,406 |
| 500 | 48.0 | 7,941 |
| 630 | 53.5 | 9,999 |
| 800 | 59.5 | 12,304 |
| Conductor Nom. Cross Sect. (mm²) | DC Resistance at 20°C Max. (Ω/km) | AC Resistance at 90°C Max. (Ω/km) | Inductance Trefoil formation (mH/km) | Flat formation (mH/km) | Current - Carrying Capacity at 30° C * in air Max. (A) | in ground Max. (A) | in air Max. (A) | in ground Max. (A) | Short circuit current at 1 sec Max. (kA) |
|---|---|---|---|---|---|---|---|---|---|
| 16 | 1.15 | 1.466 | 0.479 | 0.526 | 126 | 118 | 128 | 121 | 2.29 |
| 25 | 0.727 | 0.927 | 0.431 | 0.477 | 165 | 153 | 169 | 157 | 3.58 |
| 35 | 0.524 | 0.668 | 0.400 | 0.447 | 199 | 184 | 204 | 189 | 5.01 |
| 50 | 0.387 | 0.494 | 0.372 | 0.418 | 241 | 219 | 247 | 224 | 7.15 |
| 70 | 0.268 | 0.342 | 0.354 | 0.400 | 301 | 267 | 308 | 273 | 10.01 |
| 95 | 0.193 | 0.247 | 0.338 | 0.384 | 366 | 319 | 375 | 325 | 13.59 |
| 120 | 0.153 | 0.196 | 0.329 | 0.375 | 424 | 361 | 433 | 368 | 17.16 |
| 150 | 0.124 | 0.159 | 0.322 | 0.369 | 481 | 404 | 491 | 410 | 21.45 |
| 185 | 0.0991 | 0.128 | 0.316 | 0.363 | 553 | 454 | 563 | 459 | 26.46 |
| 240 | 0.0754 | 0.098 | 0.307 | 0.354 | 652 | 521 | 661 | 525 | 34.32 |
| 300 | 0.0601 | 0.079 | 0.301 | 0.347 | 742 | 581 | 748 | 582 | 42.90 |
| 400 | 0.0470 | 0.063 | 0.298 | 0.344 | 848 | 648 | 849 | 645 | 57.20 |
| 500 | 0.0366 | 0.051 | 0.292 | 0.338 | 965 | 719 | 959 | 708 | 71.50 |
| 630 | 0.0283 | 0.041 | 0.286 | 0.333 | 1088 | 789 | 1071 | 769 | 90.09 |
| 800 | 0.0221 | 0.034 | 0.283 | 0.329 | 1203 | 852 | 1172 | 821 | 114.40 |
N2XKBY 2 x (1.5-300) mm² 0.6/1 kV
| Nom. Cross Section Area | Overall Diameter approx. | Cable Weight approx. |
|---|---|---|
| mm² | mm | kg/km |
| 1.5 | 21.0 | 1,050 |
| 2.5 | 21.0 | 1,072 |
| 4 | 21.0 | 1,101 |
| 6 | 21.0 | 1,119 |
| 10 | 22.0 | 1,254 |
| 16 | 24.0 | 1,517 |
| 25 | 27.0 | 1,934 |
| 35 | 29.0 | 2,303 |
| 50 | 32.0 | 2,849 |
| 70 | 36.5 | 3,745 |
| 95 | 42.0 | 5,142 |
| 120 | 46.0 | 6,178 |
| 150 | 51.0 | 7,426 |
| 185 | 56.0 | 8,981 |
| 240 | 62.5 | 11,256 |
| 300 | 68.5 | 13,513 |
| Conductor Nom. Cross Sect. (mm²) | DC Resistance at 20°C Max. (Ω/km) | AC Resistance at 90°C Max. (Ω/km) | Inductance | Current - Carrying Capacity at 30°C * in air Max. (A) | in ground Max. (A) | Short circuit current at 1 sec Max. (kA) |
|---|---|---|---|---|---|---|
| (mH/km) | ||||||
| 1.5 | 12.1 | 15.429 | 0.340 | 30 | 33 | 0.21 |
| 2.5 | 7.41 | 9.449 | 0.315 | 40 | 44 | 0.36 |
| 4 | 4.61 | 5.878 | 0.285 | 53 | 57 | 0.57 |
| 6 | 3.08 | 3.927 | 0.263 | 67 | 73 | 0.86 |
| 10 | 1.83 | 2.334 | 0.248 | 92 | 99 | 1.43 |
| 16 | 1.15 | 1.467 | 0.238 | 122 | 129 | 2.29 |
| 25 | 0.727 | 0.927 | 0.240 | 160 | 166 | 3.58 |
| 35 | 0.524 | 0.669 | 0.233 | 197 | 200 | 5.01 |
| 50 | 0.387 | 0.494 | 0.232 | 237 | 237 | 7.15 |
| 70 | 0.268 | 0.342 | 0.229 | 298 | 291 | 10.01 |
| 95 | 0.193 | 0.247 | 0.224 | 366 | 348 | 13.59 |
| 120 | 0.153 | 0.196 | 0.223 | 423 | 395 | 17.16 |
| 150 | 0.124 | 0.160 | 0.224 | 481 | 442 | 21.45 |
| 185 | 0.0991 | 0.128 | 0.225 | 548 | 496 | 26.46 |
| 240 | 0.0754 | 0.099 | 0.223 | 645 | 572 | 34.32 |
| 300 | 0.0601 | 0.080 | 0.221 | 731 | 639 | 42.90 |
N2XKBY 3 x (1.5-300) mm² 0.6/1 kV
| Nom. Cross Section Area | Overall Diameter approx. | Cable Weight approx. |
|---|---|---|
| mm² | mm | kg/km |
| 1.5 | 21.0 | 1,068 |
| 2.5 | 21.0 | 1,084 |
| 4 | 21.0 | 1,112 |
| 6 | 21.0 | 1,165 |
| 10 | 22.5 | 1,398 |
| 16 | 25.0 | 1,719 |
| 25 | 28.0 | 2,229 |
| 35 | 31.0 | 2,779 |
| 50 | 33.0 | 3,134 |
| 70 | 39.0 | 4,517 |
| 95 | 43.0 | 5,680 |
| 120 | 46.5 | 6,771 |
| 150 | 51.5 | 8,186 |
| 185 | 57.0 | 9,890 |
| 240 | 63.5 | 12,518 |
| 300 | 68.5 | 14,958 |
| Conductor Nom. Cross Sect. (mm²) | DC Resistance at 20°C Max. (Ω/km) | AC Resistance at 90°C Max. (Ω/km) | Inductance | Current - Carrying Capacity at 30°C * in air Max. (A) | in ground Max. (A) | Short circuit current at 1 sec Max. (kA) |
|---|---|---|---|---|---|---|
| (mH/km) | ||||||
| 1.5 | 12.1 | 15.429 | 0.340 | 26 | 28 | 0.21 |
| 2.5 | 7.41 | 9.449 | 0.304 | 34 | 37 | 0.36 |
| 4 | 4.61 | 5.878 | 0.285 | 45 | 49 | 0.57 |
| 6 | 3.08 | 3.927 | 0.263 | 57 | 62 | 0.86 |
| 10 | 1.83 | 2.334 | 0.248 | 78 | 83 | 1.43 |
| 16 | 1.15 | 1.467 | 0.238 | 103 | 108 | 2.29 |
| 25 | 0.727 | 0.927 | 0.240 | 136 | 139 | 3.58 |
| 35 | 0.524 | 0.669 | 0.233 | 167 | 168 | 5.01 |
| 50 | 0.387 | 0.494 | 0.232 | 206 | 203 | 7.15 |
| 70 | 0.268 | 0.342 | 0.229 | 261 | 249 | 10.01 |
| 95 | 0.193 | 0.247 | 0.224 | 318 | 297 | 13.59 |
| 120 | 0.153 | 0.196 | 0.223 | 368 | 338 | 17.16 |
| 150 | 0.124 | 0.160 | 0.224 | 419 | 378 | 21.45 |
| 185 | 0.0991 | 0.128 | 0.225 | 481 | 425 | 26.46 |
| 240 | 0.0754 | 0.099 | 0.223 | 564 | 489 | 34.32 |
| 300 | 0.0601 | 0.080 | 0.221 | 643 | 548 | 42.90 |
N2XKBY 4 x (1.5-300) mm² 0.6/1 kV
| Nom. Cross Section Area | Overall Diameter approx. | Cable Weight approx. |
|---|---|---|
| mm² | mm | kg/km |
| 1.5 | 21.0 | 1,074 |
| 2.5 | 21.0 | 1,090 |
| 4 | 21.0 | 1,136 |
| 6 | 22.0 | 1,269 |
| 10 | 24.0 | 1,598 |
| 16 | 26.5 | 1,991 |
| 25 | 30.5 | 2,705 |
| 35 | 33.5 | 3,304 |
| 50 | 37.5 | 3,988 |
| 70 | 44.0 | 5,683 |
| 95 | 48.5 | 7,140 |
| 120 | 53.5 | 8,667 |
| 150 | 60.0 | 10,554 |
| 185 | 65.0 | 12,765 |
| 240 | 72.0 | 16,137 |
| 300 | 78.0 | 19,280 |
| Conductor Nom. Cross Sect. (mm²) | DC Resistance at 20°C Max. (Ω/km) | AC Resistance at 90°C Max. (Ω/km) | Inductance | Current - Carrying Capacity at 30°C * in air Max. (A) | in ground Max. (A) | Short circuit current at 1 sec Max. (kA) |
|---|---|---|---|---|---|---|
| (mH/km) | ||||||
| 1.5 | 12.1 | 15.429 | 0.328 | 29 | 31 | 0.21 |
| 2.5 | 7.41 | 9.449 | 0.304 | 38 | 41 | 0.36 |
| 4 | 4.61 | 5.878 | 0.275 | 50 | 54 | 0.57 |
| 6 | 3.08 | 3.927 | 0.263 | 63 | 68 | 0.86 |
| 10 | 1.83 | 2.334 | 0.248 | 86 | 90 | 1.43 |
| 16 | 1.15 | 1.467 | 0.238 | 113 | 117 | 2.29 |
| 25 | 0.727 | 0.927 | 0.240 | 152 | 151 | 3.58 |
| 35 | 0.524 | 0.669 | 0.233 | 185 | 181 | 5.01 |
| 50 | 0.387 | 0.494 | 0.232 | 217 | 208 | 7.15 |
| 70 | 0.268 | 0.342 | 0.229 | 273 | 254 | 10.01 |
| 95 | 0.193 | 0.247 | 0.224 | 335 | 305 | 13.59 |
| 120 | 0.153 | 0.196 | 0.223 | 387 | 345 | 17.16 |
| 150 | 0.124 | 0.160 | 0.224 | 446 | 389 | 21.45 |
| 185 | 0.0991 | 0.128 | 0.225 | 507 | 436 | 26.46 |
| 240 | 0.0754 | 0.099 | 0.223 | 595 | 501 | 34.32 |
| 300 | 0.0601 | 0.080 | 0.221 | 676 | 560 | 42.90 |
N2XKBY 5 x (1.5-50) mm² 0.6/1 kV
| Nom. ross ection Area | Overall Diameter approx. | Cable Weight approx. |
|---|---|---|
| mm² | mm | kg/km |
| 1.5 | 21.0 | 1,076 |
| 2.5 | 21.0 | 1,119 |
| 4 | 21.5 | 1,230 |
| 6 | 23.0 | 1,430 |
| 10 | 25.5 | 1,817 |
| 16 | 28.5 | 2,288 |
| 25 | 33.0 | 3,150 |
| 35 | 37.0 | 3,996 |
| 50 | 42.5 | 5,470 |
| Conductor Nom. Cross Sect. (mm²) | DC Resistance at 20°C Max. (Ω/km) | AC Resistance at 90°C Max. (Ω/km) | Inductance | Current - Carrying Capacity at 30°C * in air Max. (A) | in ground Max. (A) | Short circuit current at 1 sec Max. (kA) |
|---|---|---|---|---|---|---|
| (mH/km) | ||||||
| 1.5 | 12.1 | 15.429 | 0.328 | 30 | 32 | 0.21 |
| 2.5 | 7.41 | 9.449 | 0.293 | 39 | 42 | 0.36 |
| 4 | 4.61 | 5.878 | 0.275 | 51 | 55 | 0.57 |
| 6 | 3.08 | 3.927 | 0.263 | 65 | 69 | 0.86 |
| 10 | 1.83 | 2.334 | 0.248 | 88 | 92 | 1.43 |
| 16 | 1.15 | 1.467 | 0.238 | 117 | 119 | 2.29 |
| 25 | 0.727 | 0.927 | 0.240 | 157 | 153 | 3.58 |
| 35 | 0.524 | 0.669 | 0.233 | 192 | 183 | 5.01 |
| 50 | 0.387 | 0.494 | 0.232 | 232 | 215 | 7.15 |
Data spesifikasi bersumber dari katalog resmi pabrik Kabelmetal Indonesia (KMI). Nilai bersifat nominal/perkiraan dan dapat berubah tanpa pemberitahuan. Hubungi kami untuk konfirmasi teknis terkini.