NYKBY
Cu / PVC / LS / PVC / ATA / PVC Deskripsi
Copper Conductor, PVC Insulated, Lead Sheathed, Double Aluminium Tape Armor, PVC Sheathed
Aplikasi
- For indoors, outdoors, in ground and in duct. Mainly on chemical industries, refineries, petrol stations and any other locations where there is a risk that solvent, fuel and other chemicals may penetrate and low mechanical damage may occur
Konstruksi Kabel
Pelajari kode penamaan kabel →Susunan lapisan NYKBY dari dalam ke luar — sesuai kode konstruksi Cu / PVC / LS / PVC / ATA / PVC.
- 1
Konduktor tembaga
Copper conductorPenghantar arus utama — tembaga anil, solid / stranded / compacted.
- 2
Isolasi PVC
Polyvinyl chlorideIsolasi utama — suhu kerja 70 °C, ekonomis dan andal untuk tegangan rendah.
- 3
Selubung timah (lead sheath)
Lead sheathKedap air & tahan kimia — untuk lingkungan korosif, terkontaminasi hidrokarbon.
- 4
Selubung dalam PVC
Polyvinyl chlorideBantalan (bedding) — alas perisai/pelindung dan pengikat inti kabel.
- 5
Perisai pita aluminium (ATA)
Aluminium tape armourPerisai non-magnetik — dipakai pada kabel inti tunggal agar tidak timbul rugi induksi.
- 6
Selubung luar PVC
Polyvinyl chlorideSelubung terluar — proteksi terhadap lingkungan, kelembapan, dan abrasi.
Spesifikasi Teknis
NYKB(AL)Y 1 x (16-800) mm² 0.6/1 kV
| Nom. Cross Section Area | Overall Diameter approx. | Cable Weight approx. |
|---|---|---|
| mm² | mm | kg/km |
| 16 | 22.0 | 1,150 |
| 25 | 22.0 | 1,220 |
| 35 | 22.0 | 1,295 |
| 50 | 23.5 | 1,544 |
| 70 | 25.5 | 1,849 |
| 95 | 28.0 | 2,311 |
| 120 | 29.5 | 2,643 |
| 150 | 31.5 | 3,048 |
| 185 | 34.0 | 3,694 |
| 240 | 37.5 | 4,616 |
| 300 | 41.0 | 5,526 |
| 400 | 45.5 | 6,862 |
| 500 | 49.5 | 8,287 |
| 630 | 54.5 | 10,299 |
| 800 | 60.0 | 12,573 |
| Conductor Nom. Cross Sect. (mm²) | DC Resistance at 20°C Max. (Ω/km) | AC Resistance at 70°C Max. (Ω/km) | Inductance Trefoil formation (mH/km) | Flat formation (mH/km) | Current - Carrying Capacity at 30° C * in air Max. (A) | in ground Max. (A) | in air Max. (A) | in ground Max. (A) | Short circuit current at 1 sec Max. (kA) |
|---|---|---|---|---|---|---|---|---|---|
| 16 | 1.15 | 1.376 | 0.479 | 0.526 | 101 | 98 | 103 | 101 | 1.84 |
| 25 | 0.727 | 0.870 | 0.431 | 0.477 | 132 | 128 | 135 | 131 | 2.88 |
| 35 | 0.524 | 0.627 | 0.400 | 0.447 | 160 | 154 | 164 | 157 | 4.03 |
| 50 | 0.387 | 0.463 | 0.379 | 0.426 | 193 | 182 | 198 | 186 | 5.75 |
| 70 | 0.268 | 0.321 | 0.359 | 0.405 | 241 | 222 | 247 | 227 | 8.05 |
| 95 | 0.193 | 0.232 | 0.347 | 0.393 | 294 | 265 | 300 | 270 | 10.93 |
| 120 | 0.153 | 0.184 | 0.335 | 0.381 | 338 | 301 | 345 | 305 | 13.80 |
| 150 | 0.124 | 0.150 | 0.329 | 0.375 | 384 | 335 | 391 | 340 | 17.25 |
| 185 | 0.0991 | 0.120 | 0.321 | 0.368 | 440 | 377 | 447 | 380 | 21.28 |
| 240 | 0.0754 | 0.092 | 0.313 | 0.359 | 518 | 432 | 523 | 434 | 27.60 |
| 300 | 0.0601 | 0.074 | 0.308 | 0.355 | 588 | 480 | 592 | 480 | 34.50 |
| 400 | 0.0470 | 0.059 | 0.306 | 0.352 | 670 | 534 | 669 | 529 | 41.20 |
| 500 | 0.0366 | 0.048 | 0.298 | 0.344 | 759 | 591 | 752 | 580 | 51.50 |
| 630 | 0.0283 | 0.039 | 0.290 | 0.336 | 854 | 648 | 838 | 629 | 64.89 |
| 800 | 0.0221 | 0.033 | 0.284 | 0.331 | 941 | 697 | 915 | 670 | 82.40 |
NYKBY 2 x (1.5-300) mm² 0.6/1 kV
| Nom. Cross Section Area | Overall Diameter approx. | Cable Weight approx. |
|---|---|---|
| mm² | mm | kg/km |
| 1.5 | 21.0 | 1,057 |
| 2.5 | 21.0 | 1,081 |
| 4 | 21.0 | 1,111 |
| 6 | 21.0 | 1,146 |
| 10 | 23.0 | 1,378 |
| 16 | 25.0 | 1,651 |
| 25 | 28.0 | 2,083 |
| 35 | 30.5 | 2,550 |
| 50 | 34.0 | 3,187 |
| 70 | 38.5 | 4,077 |
| 95 | 45.0 | 5,678 |
| 120 | 48.5 | 6,672 |
| 150 | 53.0 | 7,953 |
| 185 | 58.5 | 9,596 |
| 240 | 65.0 | 12,034 |
| 300 | 71.5 | 14,464 |
| Conductor Nom. Cross Sect. (mm²) | DC Resistance at 20°C Max. (Ω/km) | AC Resistance at 70°C Max. (Ω/km) | Inductance | Current - Carrying Capacity at 30°C * in air Max. (A) | in ground Max. (A) | Short circuit current at 1 sec Max. (kA) |
|---|---|---|---|---|---|---|
| (mH/km) | ||||||
| 1.5 | 12.1 | 14.478 | 0.351 | 24 | 27 | 0.17 |
| 2.5 | 7.41 | 8.866 | 0.315 | 32 | 35 | 0.29 |
| 4 | 4.61 | 5.516 | 0.303 | 42 | 47 | 0.46 |
| 6 | 3.08 | 3.685 | 0.288 | 54 | 60 | 0.69 |
| 10 | 1.83 | 2.190 | 0.269 | 73 | 80 | 1.15 |
| 16 | 1.15 | 1.376 | 0.255 | 97 | 105 | 1.84 |
| 25 | 0.727 | 0.870 | 0.255 | 127 | 135 | 2.88 |
| 35 | 0.524 | 0.627 | 0.246 | 156 | 162 | 4.03 |
| 50 | 0.387 | 0.464 | 0.247 | 187 | 191 | 5.75 |
| 70 | 0.268 | 0.321 | 0.238 | 235 | 236 | 8.05 |
| 95 | 0.193 | 0.232 | 0.238 | 287 | 280 | 10.93 |
| 120 | 0.153 | 0.184 | 0.233 | 332 | 320 | 13.80 |
| 150 | 0.124 | 0.150 | 0.233 | 377 | 358 | 17.25 |
| 185 | 0.0991 | 0.121 | 0.233 | 428 | 401 | 21.28 |
| 240 | 0.0754 | 0.093 | 0.232 | 501 | 461 | 27.60 |
| 300 | 0.0601 | 0.075 | 0.231 | 567 | 514 | 34.50 |
NYKBY 3 x (1.5-300) mm² 0.6/1 kV
| Nom. Cross Section Area | Overall Diameter approx. | Cable Weight approx. |
|---|---|---|
| mm² | mm | kg/km |
| 1.5 | 21.0 | 1,082 |
| 2.5 | 21.0 | 1,099 |
| 4 | 21.0 | 1,132 |
| 6 | 22.0 | 1,261 |
| 10 | 24.0 | 1,539 |
| 16 | 26.0 | 1,873 |
| 25 | 29.5 | 2,402 |
| 35 | 32.5 | 2,986 |
| 50 | 35.5 | 3,417 |
| 70 | 41.0 | 4,797 |
| 95 | 45.5 | 6,103 |
| 120 | 49.0 | 7,208 |
| 150 | 54.5 | 8,839 |
| 185 | 59.5 | 10,622 |
| 240 | 66.5 | 13,440 |
| 300 | 72.5 | 16,067 |
| Conductor Nom. Cross Sect. (mm²) | DC Resistance at 20°C Max. (Ω/km) | AC Resistance at 70°C Max. (Ω/km) | Inductance | Current - Carrying Capacity at 30°C * in air Max. (A) | in ground Max. (A) | Short circuit current at 1 sec Max. (kA) |
|---|---|---|---|---|---|---|
| (mH/km) | ||||||
| 1.5 | 12.1 | 14.478 | 0.351 | 21 | 23 | 0.17 |
| 2.5 | 7.41 | 8.866 | 0.315 | 27 | 30 | 0.29 |
| 4 | 4.61 | 5.516 | 0.303 | 36 | 40 | 0.46 |
| 6 | 3.08 | 3.685 | 0.288 | 46 | 51 | 0.69 |
| 10 | 1.83 | 2.190 | 0.269 | 63 | 68 | 1.15 |
| 16 | 1.15 | 1.376 | 0.255 | 83 | 89 | 1.84 |
| 25 | 0.727 | 0.870 | 0.255 | 108 | 114 | 2.88 |
| 35 | 0.524 | 0.627 | 0.246 | 133 | 137 | 4.03 |
| 50 | 0.387 | 0.464 | 0.247 | 166 | 168 | 5.75 |
| 70 | 0.268 | 0.321 | 0.238 | 210 | 206 | 8.05 |
| 95 | 0.193 | 0.232 | 0.238 | 257 | 246 | 10.93 |
| 120 | 0.153 | 0.184 | 0.233 | 296 | 280 | 13.80 |
| 150 | 0.124 | 0.150 | 0.233 | 336 | 312 | 17.25 |
| 185 | 0.0991 | 0.121 | 0.233 | 385 | 352 | 21.28 |
| 240 | 0.0754 | 0.093 | 0.232 | 451 | 404 | 27.60 |
| 300 | 0.0601 | 0.075 | 0.231 | 513 | 452 | 34.50 |
NYKBY 4 x (1.5-300) mm² 0.6/1 kV
| Nom. Cross Section Area | Overall Diameter approx. | Cable Weight approx. |
|---|---|---|
| mm² | mm | kg/km |
| 1.5 | 21.0 | 1,077 |
| 2.5 | 21.0 | 1,113 |
| 4 | 22.0 | 1,246 |
| 6 | 23.5 | 1,421 |
| 10 | 25.5 | 1,766 |
| 16 | 28.0 | 2,175 |
| 25 | 32.0 | 2,933 |
| 35 | 35.5 | 3,655 |
| 50 | 42.5 | 4,827 |
| 70 | 46.0 | 6,047 |
| 95 | 52.5 | 7,932 |
| 120 | 57.0 | 9,433 |
| 150 | 63.5 | 11,427 |
| 185 | 68.5 | 13,621 |
| 240 | 76.0 | 17,132 |
| 300 | 83.0 | 20,793 |
| Conductor Nom. Cross Sect. (mm²) | DC Resistance at 20°C Max. (Ω/km) | AC Resistance at 70°C Max. (Ω/km) | Inductance | Current - Carrying Capacity at 30°C * in air Max. (A) | in ground Max. (A) | Short circuit current at 1 sec Max. (kA) |
|---|---|---|---|---|---|---|
| (mH/km) | ||||||
| 1.5 | 12.1 | 14.478 | 0.340 | 24 | 27 | 0.17 |
| 2.5 | 7.41 | 8.866 | 0.315 | 32 | 35 | 0.29 |
| 4 | 4.61 | 5.516 | 0.303 | 42 | 47 | 0.46 |
| 6 | 3.08 | 3.685 | 0.288 | 53 | 58 | 0.69 |
| 10 | 1.83 | 2.190 | 0.269 | 72 | 77 | 1.15 |
| 16 | 1.15 | 1.376 | 0.255 | 94 | 100 | 1.84 |
| 25 | 0.727 | 0.870 | 0.255 | 126 | 128 | 2.88 |
| 35 | 0.524 | 0.627 | 0.246 | 154 | 153 | 4.03 |
| 50 | 0.387 | 0.464 | 0.247 | 178 | 173 | 5.75 |
| 70 | 0.268 | 0.321 | 0.238 | 222 | 212 | 8.05 |
| 95 | 0.193 | 0.232 | 0.238 | 272 | 254 | 10.93 |
| 120 | 0.153 | 0.184 | 0.233 | 313 | 287 | 13.80 |
| 150 | 0.124 | 0.150 | 0.233 | 360 | 323 | 17.25 |
| 185 | 0.0991 | 0.121 | 0.233 | 406 | 361 | 21.28 |
| 240 | 0.0754 | 0.093 | 0.232 | 478 | 415 | 27.60 |
| 300 | 0.0601 | 0.075 | 0.231 | 542 | 463 | 34.50 |
NYKBY 5 x (1.5-50) mm² 0.6/1 kV
| Nom. Cross Section Area | Overall Diameter approx. | Cable Weight approx. |
|---|---|---|
| mm² | mm | kg/km |
| 1.5 | 21.0 | 1,105 |
| 2.5 | 21.0 | 1,131 |
| 4 | 23.5 | 1,400 |
| 6 | 25.0 | 1,610 |
| 10 | 27.5 | 2,014 |
| 16 | 30.5 | 2,591 |
| 25 | 35.0 | 3,522 |
| 35 | 40.0 | 4,783 |
| 50 | 45.5 | 6,064 |
| Conductor Nom. Cross Sect. (mm²) | DC Resistance at 20°C Max. (Ω/km) | AC Resistance at 70°C Max. (Ω/km) | Inductance | Current - Carrying Capacity at 30°C * in air Max. (A) | in ground Max. (A) | Short circuit current at 1 sec Max. (kA) |
|---|---|---|---|---|---|---|
| (mH/km) | ||||||
| 1.5 | 12.1 | 14.478 | 0.340 | 25 | 27 | 0.17 |
| 2.5 | 7.41 | 8.866 | 0.304 | 32 | 36 | 0.29 |
| 4 | 4.61 | 5.516 | 0.303 | 43 | 47 | 0.46 |
| 6 | 3.08 | 3.685 | 0.288 | 54 | 59 | 0.69 |
| 10 | 1.83 | 2.190 | 0.269 | 74 | 79 | 1.15 |
| 16 | 1.15 | 1.376 | 0.255 | 98 | 101 | 1.84 |
| 25 | 0.727 | 0.870 | 0.255 | 130 | 130 | 2.88 |
| 35 | 0.524 | 0.627 | 0.246 | 160 | 155 | 4.03 |
| 50 | 0.387 | 0.464 | 0.247 | 192 | 182 | 5.75 |
Data spesifikasi bersumber dari katalog resmi pabrik Kabelmetal Indonesia (KMI). Nilai bersifat nominal/perkiraan dan dapat berubah tanpa pemberitahuan. Hubungi kami untuk konfirmasi teknis terkini.
Minta penawaran untuk NYKBY